Carrier Furnace Service Manual Model 58mxa060

Posted on
Carrier Furnace Service Manual Model 58mxa060 Rating: 4,9/5 5349 votes

. Series 111 Input Capacities: 40,000 thru 120,000 Btuh 4-way Multipoise Design Allows More Applications. The model 58MXA is a must for your product line. This high-efficiency furnace allows more applications with its reliable 4-way multipoise design. The model 58MXA is available in 10. The model Warranty on the heat exchangers for the Adjustable Blower Speed —For 58MXA is equipped for either left- or lifetime of original owner in single precise airflow selection of heating or right-side connections. Blower speeds family residence.

  1. Carrier Furnace Service Manual
Furnace

Provides easy access for exit in a roof or sidewall. A Carrier humidifier will add included.

View and Download Carrier 58MSA service and maintenance instructions online. 4-Way Multipoise Fixed-Capacity Condensing Gas Furnace. 58MSA Furnace pdf manual download.

Cleaning filter. Accepts one moisture to winter-dry air to 16 x 25 x 1 in. A93202 NOTES: 1.

The 58MXA Furnaces are for use with natural gas, but can be field-converted for propane gas with a factory-authorized and listed accessory conversion kit. Component location and configuration may be different than shown above. Combustion-air intake connection to ensure Secondary condensing heat exchanger (inside). Physical data UNIT SIZE 040-08 040-12 060-12 060-16 080-12 080-16 080-20 100-16 100-20 120-20 OUTPUT CAPACITY BTUH† (Nonweatherized ICS) 37,200 37,200 55,800 55,800 74,400 74,400 74,400 93,000 93,000 111,600 INPUT BTUH.

40,000 40,000 60,000 60,000 80,000 80,000 80,000 100,000 100,000 120,000 SHIPPING WEIGHT (Lb) CERTIFIED TEMP RISE RANGE ( °. Dimensions ⁄ ' ⁄ ' ⁄ ' ⁄ ' AIRFLOW ⁄ ' ⁄ ' ⁄ ' ⁄ ' ⁄ ' 19' ⁄ ⁄ ⁄ ' ' ' 2-IN. COMBUSTION- ⁄ ' CONDENSATE DRAIN AIR CONN OUTLET OUTLET TRAP LOCATION (DOWNFLOW & CONDENSATE DRAIN 2-IN. CONDENSATE TRAP FURNACE BLOWER SHELF CONDENSATE DOOR TRAP FURNACE CONDENSATE DOOR FURNACE TRAP (INSIDE) FURNACE SIDE SIDE FIELD FIELD DRAIN DRAIN ALTERNATE DRAIN CONN CONN TUBE LOCATION SIDE VIEW FRONT VIEW END VIEW FRONT VIEW CONDENSATE TRAP DRAIN TUBE LOCATION DOWNFLOW AND ALTERNATE HORIZONTAL UPFLOW APPLICATIONS. Performance data UNIT SIZE 040-08 040-12 060-12 060-16 080-12 080-16 080-20 100-16 100-20 120-20 DIRECT-DRIVE MOTOR Hp (PSC) MOTOR FULL LOAD AMPS 11.1 11.1 11.1 RPM (Nominal)—SPEEDS 1075—3 1075—4 BLOWER WHEEL DIAMETER X WIDTH (In.) 10 x 6 10 x 7 10 x 7 11 x 8 10 x 7. Electrical data UNIT SIZE 040-08 040-12 060-12 060-16 080-12 080-16 080-20 100-16 100-20 120-20 UNIT VOLTS—HERTZ—PHASE 115—60—1 OPERATING VOLTAGE RANGE (Min—Max)† 104—127 MAXIMUM UNIT AMPS 10.0 14.1 10.2 14.8 14.6 UNIT AMPACITY. 10.0 12.8 10.4 13.4 18.4 13.5 19.3 19.1 MINIMUM WIRE SIZE MAXIMUM WIRE LENGTH (Ft).

MAXIMUM FUSE SIZE OR CKT BKR (Amps)‡. Combustion-air and vent piping MAXIMUM ALLOWABLE PIPE LENGTH (FT) ALTITUDE NUMBER OF 90° ELBOWS ABOVE SEA UNIT SIZE TERMINATION TYPE PIPE DIA LEVEL (FT) (IN.).

040-08 2 Pipe or 2-In. Concentric 1-1/2 040-12 1-1/2 060-12 2 Pipe or 2-In.

Concentric 060-16 1-1/2 080-12. MAXIMUM ALLOWABLE PIPE LENGTH (FT) Continued ALTITUDE NUMBER OF 90° ELBOWS ABOVE SEA PIPE DIA LEVEL (FT) UNIT SIZE TERMINATION TYPE (IN.). 1-1/2 040-08 2 Pipe or 2-In. Concentric 040-12 1-1/2 060-12 2 Pipe or 2-In. Concentric 060-16 0 to 7000‡ 2 Pipe or 2-In. MAXIMUM ALLOWABLE EXPOSED VENT PIPE LENGTH (FT) WITH INSULATION IN WINTER DESIGN TEMPERATURE AMBIENT. INSULATION THICKNESS (IN.)† WINTER DESIGN MAXIMUM PIPE TEMP °F UNIT SIZE 1-1/2 040-08 1-1/2 040-12 –20 1-1/2 060-12 060-16 –20 2-1/2 080-12 080-16 2-1/2 080-20 –20 2-1/2 100-16 100-20.

Carrier Furnace Service Manual

Typical installations Basement — Upflow Application A93063 Closet — Downflow Application A93064. Syracuse, New York 13221 7-94 Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations Book Page 14 Catalog No. 525-861 Printed in U.S.A. PC 101 Form 58MXA-2PD Replaces: 58MXA-1PD 6a 8a.