Carrier Series 160 Manual

Posted on
Carrier Series 160 Manual Rating: 4,6/5 6719 votes

. Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations. Book 1 4 PC 101 Catalog No.

  1. Carrier Series 160
  2. Carrier Furnace 58sta/stx Series 160 Manual

535-80099 Printed in U.S.A. Form 58MXA-9SM Pg 1 11-02 Replaces: 58MXA-8SM Tab 6a 8a. AIRFLOW EFFICIENCY RATING CERTIFIED UPFLOW CERTIFIED ® HORIZONTAL HORIZONTAL LEFT RIGHT DOWNFLOW AIRFLOW AIRFLOW REGISTERED QUALITY SYSTEM AIRFLOW SAFETY CONSIDERATIONS A93041 Recognize safety information. This is the safety-alert symbol Fig.

Carrier Series 160 Manual

M60A2: AN/VRC-53 AN/VRC-64 AN/GRC-125 AN/GRC-160 M60A3 or M60A1. AN/GRC-160 Radio sets carrier, command post M577, M577A1: AN/VRC-53. For all single-reduction differential carriers. Axle Model Series, Refer to Maintenance Manual 5A. D-140 F-121 H-170 QT-140 R-160.

2—Multipoise Orientation When you see this symbol on the furnace and in instructions or ELECTROSTATIC DISCHARGE (ESD) PRECAUTIONS manuals, be alert to the potential for personal injury. WASHABLE FILTER IN FURNACE FILTER RETAINER WASHABLE FILTER FILTER SUPPORT FILTER RETAINER WASHABLE FILTER OR DISPOSABLE MEDIA WASHABLE FILTER OR FILTER IN FILTER CABINET DISPOSABLE MEDIA FILTER IN FILTER CABINET A00233 Fig. 4—Filter Installed for Side Inlet A00232 Fig.

3—Bottom Filter Arrangement To clean or replace filters, proceed as follows: If filter is installed in filter cabinet adjacent to furnace: Turn off the gas and electrical supplies to the unit before. Clean blower motor and wheel as follows: (1.) Connect 1 tube (blue or blue and white striped) from collector box. Turn off electrical supply to furnace. (2.) Connect 1 tube (violet or unmarked) from inducer 2. Remove main furnace door and blower access panel. Remove burner box pressure tube from gas valve regulator fitting. FIRE OR EXPLOSION HAZARD 7.

Remove screws that secure manifold to burner box. Failure to follow the safety warnings exactly could result in serious injury, death, or property damage. Never test for gas leaks with an open flame.

Check furnace operation through 2 complete heat operating PRIMARY HX INLET OPENINGS cycles. Look through sight glass in burner enclosure to check burners. Burner flames should be clear blue, almost transpar- ent. 9.) FIRE OR EXPLOSION HAZARD Failure to follow the safety warnings exactly could result in serious injury, death, or property damage. TUBE ROUTING Furnace is shipped from factory in upflow configuration. Pressure tube and drain tube routing MUST match the diagrams below.

Tube location when used in UPFLOW application Condensate Trap on LEFT Condensate Trap; Factory Installed Side Optional in Blower Shelf BURNER ENCLOSURE (Blower access panel removed) BURNER ENCLOSURE. Turn off gas and electrical supplies to furnace. Remove main furnace door. Disconnect igniter wire connection.

Check igniter resistance. Using an ohm meter, check resistance across both igniter leads in connector. Cold reading should be between 45 ohms and 90 ohms. FIELD 24-V WIRING FIELD 115-, 208/230-, 460-V WIRING FACTORY 24-V WIRING FACTORY 115-V WIRING NOTE 2 THERMOSTAT FIVE WIRE FIELD-SUPPLIED TERMINALS DISCONNECT THREE-WIRE HEATING-ONLY 208/230- OR BLOWER DOOR SWITCH 460-V THREE PHASE 208/230-V SINGLE PHASE AUXILIARY 115-V FIELD- J-BOX SUPPLIED NOTE 1 DISCONNECT CONDENSING. 32 F MINIMUM INSTALLED AMBIENT OR FREEZE PROTECTION REQUIRED A93058 Fig.

Manual

13—Winterizing the Furnace Step 8—Checking Heat Tape Operation (If Applicable) If this furnace is to be operated in an unconditioned space where the ambient temperatures may be 32°F or lower, freeze protection measures must be taken. Reconnect drain cap to inducer housing. Record the code. After the last code is displayed the control will perform the component test, and then return to normal standby 7. Replace main furnace door. Propylene glycol need not be removed before restarting furnace. TO 115VAC FIELD DISCONNECT SCHEMATIC DIAGRAM (WHEN USED) BLOWER OFF DELAY LGPS NOTE #2 (NATURAL GAS & PROPANE) JUMPER SELECT EQUIPMENT GROUND DHUM CAP-1 MED LO NOTE #11 HEAT MED HI START SPARE-1 NOTE #10 HI/LO BLWR COOL EAC-2 Y/Y2 TEST/TWIN BLWM EAC-1.

Haynes manual 2017 s10. Our library is the biggest of these that have literally hundreds of thousands of different products represented.

Manual

SERVICE If status code recall is needed, briefly remove then reconnect one main limit wire to display stored status code. On RED LED boards do not remove power or blower door before initiat- ing status code recall. After one status code recall is completed component test will occur. LED CODE STATUS CONTINUOUS OFF - Check for 115VAC at L1 &. Copyright 2002 CARRIER Corp. Indianapolis, IN 46231 58mxa9sm Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations.

Carrier Series 160

Book 1 4 Tab 6a 8a PC 101 Catalog No.

Carrier Furnace 58sta/stx Series 160 Manual

Carrier furnaces provide homeowners with essential warmth during the winter months and help circulate air from their cooling systems during hot summer weather. Designed for reliability and durability, these furnaces offer the energy-efficient heating and cooling you need to keep costs down. Keep your Carrier furnace in top-notch operating condition by using Sears PartsDirect for all your maintenance and repair parts.

Quiet Operation Carrier furnaces operate quietly, helping you maintain peace in your home. However, loose or displaced parts in the blower assembly may come loose or become damaged, making your unit operate at sound levels that disturb you and your family. Find quick fixes for noisy furnaces at Sears PartsDirect, and order replacement compatible with your specific model. Proper Gas Flow Carrier furnaces use gas to heat your home. The gas also powers your furnace's blowers when it circulates air from your cooling system.

This makes proper gas flow very important to the operation of your unit and to your family's safety. When breakdowns occur, use Sears PartsDirect to repair issues with gas flow by ordering replacement parts such as gaskets, casings and closures. Simple Controls Carrier furnaces feature easy-to-use control panels that allow you to adjust their settings. If your unit's control panel fails to fire properly or if the transformer fails, repair help and replacement parts designed for use with your furnace model stand available at Sears PartsDirect. Your Carrier furnace ensures your home stays warm in the winter and cool in the summer. Ensure this vital appliance operates at optimal efficiency and safety using the resources and parts available at Sears PartsDirect. To get started, simply choose your model from the list above, click the chat button or call 1-800-252-1698.